Skip to content

Coupling Networks - Power Lines

Coupling decoupling networks are used to extend the testing capabilities of transient generators. Ametek CTS offers a wide variety of networks to couple on power (mains) lines. For each of the generator families a choice of different power line coupling networks are available.

  • PCN 7-R s-1

    Coupling network for manual coupling with an impedance of 42 Ω, 0.5 uF according EN 50121 standards.

    Keep Reading
  • CDN 3000A series

    Three phase automatic 32 A coupling/decoupling networks (CDNs) for EFT/Burst and Surge

    Keep Reading
  • CDN 3153 series

    Three phase automatic 63 A coupling/decoupling networks (CDNs) for Surge testing acc IEC 61000-4-5

    Keep Reading
  • coupling NX7 series

    3-phase coupling/decoupling network for EFT/burst, Surge Ringwave. Available for 16A , 32 A, 63 A, 125 A and 200 A.

    Keep Reading
  • coupling NX5 series

    3-phase coupling/decoupling network for EFT/burst and Surge. Available for 16A , 32 A, 63 A, 125 A and 200 A.

    Keep Reading
  • PCD 8 s-3-690-1000 series

    Coupling/decoupling network for surge pulses on high voltage supply lines up to 3 * 690 V AC, 1.000 V DC, models for 100 and 200 A available. Pulses are coupled manually.

    Keep Reading
  • PCD 8 b-3-690-1000 series

    Coupling/decoupling network for burst pulses on high voltage supply lines up to 3 * 690 V AC, 1.000 V DC, models for 100 and 200 A available. Pulses are coupled in common mode (all lines simultaneously).

    Keep Reading
  • PCD 8-DC b-1-1500-400

    Coupling/decoupling network for burst pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 400 A. Pulses are coupled in common mode (all lines simultaneously).

    Keep Reading
  • PCD 6-DC s-1-1400-400

    Coupling/decoupling network for surge pulses up to 6 kV on high voltage DC supply lines up to 1.400 V DC, 400 A. Pulses are coupled manually.

    Keep Reading
  • PCD 8-DC s-1-1500-400

    Coupling/decoupling network for surge pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 400 A. Pulses are coupled manually.

    Keep Reading
  • PCD 8-DC s-1-1500-200

    Coupling/decoupling network for surge pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 200 A. Pulses are coupled manually.

    Keep Reading
  • PCD 8-DC family

    Coupling/decoupling network for surge pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 400 A. Pulses are coupled manually.

    Keep Reading
  • PCD 8-DC surge series

    Coupling/decoupling network for surge pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 400 A. Pulses are coupled manually.

    Keep Reading
  • PCD 8-DC burst series

    Coupling/decoupling network for burst pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 400 A. Pulses are coupled in common mode (all lines simultaneously).

    Keep Reading