Automotive Electrical Disturbances
Transient Immunity
Transient Emissions
Automotive Electrical Disturbances Accessories
Automotive Supply Voltage Variations
Ripple Generators and Couplers
Dips and Interrupts Generators and Modules
LV 124 and LV 148 Systems and Components
Arbitrary Waveform Generators
Accessories
Automotive Battery Simulators
Four-Quadrant Battery Simulators
One- and Three-Quadrant Battery Simulators
Electrostatic Discharge ESD
16.5 kV
30 kV
Harmonics & Flicker
Analyzers
Power Sources
Flicker Impedances
Programmable AC/DC Power Sources
Single Phase
Three Phase
Options & Accessories
Dips, Interrupts & Variations
Power Fail Simulators
Stepped Transformers
Motor Variacs
Ring Wave / Damped Oscillatory
Ringwave Generator
Damped Oscillatory Wave
Coupling Networks
Transient Generators (Surge, Burst)
Compact Generator 5 kV
Compact Generator 7 kV
Burst Generator
Surge Generator
Telecom Surge
Voltage Surge (1.2/50 us)
Current Surge (8/20 us)
Coupling Networks - Data Lines
Coupling Networks - Power Lines
Transient Accessories
Magnetic Fields
Magnetic Fields for Automotive Applications
Field Generator
Magnetic Field Antennas
Amplifiers - Solid State
< 1 GHz
< 6 GHz - Single Band
< 6GHz - Dual Band
Amplifiers - CW TWT
< 4 GHz
< 8 GHz
< 12 GHz
< 18 GHz
Amplifiers - Pulsed TWT
Amplifiers - Millimeter TWT Amplifiers
< 26 GHz
< 40 GHz
RF Immunity Test Systems
High Frequency Generators
Low Frequency Generators
Broadband Noise Generators
Software
RF Coupling Networks/ LISN
CDN| EM TEST | Teseq
CDND
CDNE
CN
CT
LISN or AMN
ISN or AAN
RF Probes and Clamps
Absorbing Clamps / Ferrite Tubes
EM Clamps
Current Injection Probes
Current Sensing Probes
Capacitive Voltage Probe
RF System Components and Accessories
Power Amplifiers
Preamplifiers
Power Meters
RF Switches
Attenuators
Directional Couplers
Reference Sources
Cables / Kits
GTEM / TEM Cells / Striplines / Reverberation Chambers
GTEM Cells
Predefined GTEM Systems
TEM Cells
Reverberation Chambers / Stirrers
Striplines
Antennas
Bilog
Horn
Loop
Coupling decoupling networks are used to extend the testing capabilities of transient generators. Ametek CTS offers a wide variety of networks to couple on power (mains) lines. For each of the generator families a choice of different power line coupling networks are available.
Coupling network for manual coupling with an impedance of 42 Ω, 0.5 uF according EN 50121 standards.
Three phase automatic 32 A coupling/decoupling networks (CDNs) for EFT/Burst and Surge
Three phase automatic 63 A coupling/decoupling networks (CDNs) for Surge testing acc IEC 61000-4-5
3-phase coupling/decoupling network for EFT/burst, Surge Ringwave. Available for 16A , 32 A, 63 A, 125 A and 200 A.
3-phase coupling/decoupling network for EFT/burst and Surge. Available for 16A , 32 A, 63 A, 125 A and 200 A.
Coupling/decoupling network for surge pulses on high voltage supply lines up to 3 * 690 V AC, 1.000 V DC, models for 100 and 200 A available. Pulses are coupled manually.
Coupling/decoupling network for burst pulses on high voltage supply lines up to 3 * 690 V AC, 1.000 V DC, models for 100 and 200 A available. Pulses are coupled in common mode (all lines simultaneously).
Coupling/decoupling network for burst pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 400 A. Pulses are coupled in common mode (all lines simultaneously).
Coupling/decoupling network for surge pulses up to 6 kV on high voltage DC supply lines up to 1.400 V DC, 400 A. Pulses are coupled manually.
Coupling/decoupling network for surge pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 400 A. Pulses are coupled manually.
Coupling/decoupling network for surge pulses up to 8 kV on high voltage DC supply lines up to 1.500 V DC, 200 A. Pulses are coupled manually.