--------------------------------------------- 2021-08-20 Version 1.15 - Fixed a bug that caused an overcurrent error for specific devices --------------------------------------------- --------------------------------------------- 2021-05-30 Version 1.14 - Now fully supporting expert mode for icd.control --------------------------------------------- --------------------------------------------- - Version 1.13 - Update only for internal testing - Release omitted --------------------------------------------- --------------------------------------------- 2021-02-19 Version 1.12 - Fixed a bug that caused timing problems when using 61000-4-19 with icd.control - Fixed a bug that disabled polarity change for DC signals - Fixed a bug that triggered an overcurrent error which was caused by specific conditions only on specific devices - Fixed a minor bug on startup that always caused the device to boot into test wizard. The device will now boot according to the selected menu set in Setup --------------------------------------------- --------------------------------------------- 2020-03-05 Version 1.11 - Fixed a bug with the remote port that occured when too many commands were being processed at once. - Fixed minor GUI issues. - Fixed USB serial port for newer devices. - Added trace for stress sensor 2. - Improved performance of the GUI. --------------------------------------------- --------------------------------------------- 2018-05-22 Version 1.10 Revision K - minor changes in HV generation; noticable during calibration only; no changes for user --------------------------------------------- --------------------------------------------- 2018-04-10 Version 1.10 Revision J fixes - single-shot mode inoperable for extensions other than NSG 4060-1 - adjustment to the amplifier temperature watchdog: due to slow sensor response at higher temperatures the measurement receives an offset in that region --------------------------------------------- --------------------------------------------- 2017-04-10 Version 1.10 Revision I fixes - minor changes in probe handling - improved behaviour when changing from internal DC to AC while test still running --------------------------------------------- --------------------------------------------- 2017-02-06 Version 1.10 Revision E fixes - instability issue in test wizard 61000-4-16 sweep test which was introduced with the software version prior to this revision --------------------------------------------- --------------------------------------------- 2017-02-06 Version 1.10 Revision C fixes - version 1.10 had issues when going from external DC in negative polarity back to internal AC (and the other way round also) additional notes: - to be able to fully use NSG 4060-1 type B and reverting polarity of external DC, it is required to update the MCU firmware to "SV 2.17" --------------------------------------------- --------------------------------------------- 2017-01-27 Version 1.10 Revision B new - loop level adjustment via sensor probe now takes control level overdrive and non-linearity of output vs. input into consideration fixes - version 1.10 ignored modulation setup in the wizard's 61000-4-19 tests additional notes: - to be able to fully use NSG 4060-1 type B and the new sensor port capabilities, it is required to update the MCU firmware to "SV 2.17" --------------------------------------------- --------------------------------------------- 2016-12-08 Version 1.10 new: - base unit in combination with NSG4060-1 type B can revert polarity (negative voltage) in respect to ground - base unit configuration can be saved to and restored from USB flash drive - front sensor port and analog monitoring port can now be utilized as probe for closed loop level adjustment fixes - version 1.09 failed to update the generator when a change in modulation frequency occurred additional notes: - to be able to fully use NSG 4060-1 type B and the new sensor port capabilities, it is required to update the MCU firmware to "SV 2.17" --------------------------------------------- --------------------------------------------- 2016-08-18 Version 1.09A new: - base unit is capable of performing remote control to the external DC source CHROMA 62024P (via RS232) - base unit can make use of CN EN 60255-26 (selection of coupling paths depending on test severity and also depending on differential or common mode coupling via User port) ---------------------------------------------